Installation

Standard installation of fuel cell system

Connect the fuel cell system to the city gas and tap water pipes as well as the 220V system and air flue for the boiler to complete the installation. Standard installation contents are subject to change depending on the installation location and the number of systems installed.
* For the specific installation method and precautions, refer to the manual provided with the purchased product.


Precautions

  • - Do NOT use rubber tubes for gas.
  • - Do NOT use gas other than specified (LNG, 13A).
  • - Pipe installation should be performed by professional installation specialists.
  • - Make sure to connect the drain pipe to the drain.
  • - The gas supply facility of the fuel cell system must comply with the “Facility/Technical/Inspection Standards of Facilities using KGS FU551,” and safety must be confirmed by a facility completion inspection as well as regular inspection.

Precautions

  • - Make sure to ground the fuel cell system.
  • - Be careful of electric shock when wiring fuel cells.
  • - Do NOT connect the load between the fuel cell and circuit breaker.
  • - Observe the connection conditions of the system operator.

Precautions

  • - The fuel cell system must be installed with a single exhaust format (use of two or more joint exhausts is prohibited by law).
  • - Use products certified by the Korea Gas Safety Corporation for the supply and exhaust air flue.
  • - Make sure the corrugated pipe for the supply air flue is installed upward.
  • - Do NOT use commercially available aluminum corrugated pipes.
  • - Do NOT change the shape or structure of the supply and exhaust air flue.